LUNARIS™ Human 4-Plex Complement Kit

Quantification of complement factors and proteins involved in classical and alternative complement pathways including C3a protein, CFD protein (complement factor D), CFI (complement factor I), and sC5b-9 (soluble terminal complement complex).

LUNARIS™ Kits include all components necessary to perform the assay and readout on the LUNARIS™ Reader: LUNARIS™ BioChips, diluents, buffers, reagents, standards, LUNARIS™ Decoding File, LUNARIS™ Analysis Suite, and instructions for use.

LUNARIS™ Human 4-Plex Complement Kit

Specifications

C3a CFD CFI sC5b-9

Interface adaptive/innate immunity, systemic inflammation (e.g. sepsis), ophthalmology (e.g. AMD), infectious disease (e.g. COVID-19)

Human
Aqueous humor
K2-EDTA Plasma

LUNARIS™ Products are research use only, not for use in diagnostic procedures.

Excellent Data Quality

LUNARIS™ Human 4-Plex Complement Kit

LUNARIS™ Human 4-Plex Complement Kit
Bar diagram depicting the median assay parameters (n = 10) shown in the tab ASSAY PARAMETERS. The orange bars represent the dynamic range of the assay from LoD (left border) to the ULOQ (right border). The LLOQ is depicted as a white line. Limit of detection (LoD), lower limit of quantification (LLOQ), and upper limit of quantification (ULOQ) given in pg/mL; Dynamic range (DR) on a log scale.

LUNARIS™ Human 4-Plex Complement Kit

LUNARIS™ Human 4-Plex Complement Kit
Median assay parameters determined for a ten-point standard curve (n = 10). Limit of detection (LoD), lower limit of quantification (LLOQ), and upper limit of quantification (ULOQ) given in pg/mL; Dynamic range (DR) on a log scale.

LUNARIS™ Human 4-Plex Complement Kit

LUNARIS™ Human 4-Plex Complement Kit
Superior between-run precision delivers reliable analyte quantification. Quality control samples at three different concentrations were spiked into mouse blood K2-EDTA plasma samples and markers were quantified (n = 10). Orange circles represent the mean between-run precision (BRP) of each tested analyte. The grey area denotes the required precision (< 20%).

LUNARIS™ Human 4-Plex Complement Kit

LUNARIS™ Human 4-Plex Complement Kit
Mean recovery rate from spiked mouse K2-EDTA plasma samples. Error bars represent the standard deviation of three different QC sample concentrations (n = 10). The targeted recovery range (70 to 130%) is denoted by the dotted lines/grey shaded area.

Kit Format

LUNARIS™ Kits are ready-to-use solutions and supply all components to start your multiplex protein experiment immediately.

Each kit is available in two sizes to meet your specific throughput needs and is matched with the LUNARIS™ BaseFrame for readout on the LUNARIS™ Reader 96 or 384.

The LUNARIS™ BaseFrame 96 accommodates one LUNARIS™ BioChip with 96 wells. Test up to 40 samples in a run.

The LUNARIS™ BaseFrame 384 can carry up to four 96-well LUNARIS™ BioChips, increasing your sample throughput to up to 160 samples in duplicate.

96 wells
384 wells

Ordering Information

LUNARIS™ Human 4-Plex Complement Kit

No. of BioChips Cat. No. No. of Samples*
1x96 LHCO-20040S 40
4x96 LHCO-20040F 160

*Measured in duplicate

Tailored Testing and Readout Services

Services

Outsource the labwork and focus on results. Our service experts can take over some or all the testing and readout steps. Perform the assay in your lab and send us your BioChips for readout and analysis, or engage our full service, from sample to result.

Interested in a tailored panel with your own or commercially available antibodies? Talk to our experts about our customer panel development service.

Read more / LUNARIS™ Services

Related Kits

LUNARIS™ Technology

The power of our proprietary LUNARIS™ technology lies in its elegant simplicity, which we leveraged to engineer an integrated and scalable multiplex protein analysis system, with a dedicated reader and intuitive image-based readout and data analysis.

The result is a platform that delivers transparent assay outcomes, superior data quality, workflow flexibility, and conservation of precious samples. You quantify as many as 12 biomarkers in just 3 µl of sample. You adapt the system to your throughput needs. You decide when to perform readout and how to evaluate each data point.

LUNARIS™ embodies our vision of success in translational proteomics. Validated for various biofluids, tissue samples, and cell culture, LUNARIS™ opens new opportunities in multiplex biomarker quantification to drive advances from model to man, from lab to clinic, from data to insight.

 

 

Bild entfernt.

 

Need a quote? Contact us!

If you would like a quote for any of our LUNARIS™ Kits, send us a message. We'll get back to you!

AYOXXA Newsletter

Be the first to know! Get regular news on AYOXXA and our products.

* The following fields are required for signing up our newsletter.

Connect with AYOXXA

Follow news and developments on these networks and platforms.